High-Rise Strata Window Cleaning & Sealant Inspection
The Challenge: A residential high-rise in Coal Harbour had heavy marine salt build-up on the upper windows and draft leaks reported in several south-facing suites.
Scope of Work: Clean all exterior glass windows and perform a close-up visual inspection of all sealant joints around the window frames.
Access Method: Industrial Rope Access (SPRAT/IRATA certified technicians).
The Solution: Rigged primary static ropes to certified roof anchors. Completed a two-week window cleaning drop. While detailing, our technicians inspected all exterior perimeter caulking and documented 12 cracked joints.
The Outcome: Suites received sparkling, salt-free windows, and the strata received an inspection report with photos of the failing joints, allowing them to schedule preventative sealant replacement before winter.
Inquire About Similar Project
Commercial Building Waterproofing & Exterior Coating Repair
The Challenge: Active rainwater leak in the third-floor office ceiling was traced to cracked exterior stucco cladding and failed window expansion joints.
Scope of Work: Concrete crack routing and patching, failed sealant removal, and application of a protective elastomeric coating.
Access Method: Boom lift and rope access descent.
The Solution: Routed concrete cracks, filled them with polyurethane patch materials, and replaced old polyurethane perimeter sealants with high-performance silicone. Applied two coats of commercial elastomeric wall coating.
The Outcome: Full water ingress resolved. The building facade was successfully waterproofed against wind-driven rain, and the office tenant experienced zero leaks during subsequent winter storms.
Inquire About Similar Project
Balcony Waterproofing & Leak Assessment
The Challenge: Five concrete balconies had failed vinyl sheeting that allowed water to seep into the concrete slab, causing spalling on the undersides and leaking into suites below.
Scope of Work: Remove failed vinyl sheet, repair concrete substrate, and apply a seamless, slip-resistant liquid waterproofing membrane.
Access Method: Ground scaffolding and balcony entry.
The Solution: Chipped away delaminated concrete, primed the slabs, and installed a multi-layer seamless liquid polyurethane balcony deck membrane with aggregate texture for slip-resistance.
The Outcome: Balconies are fully waterproofed and safe for resident use. The suite water leaks were resolved, preventing further internal wood framing rot.